Question:-
75. A cycloconverter is controlling a reversible ac drive in the speed range corresponding to firing angles 45° to 150°. If the highest value of the input power factor is 0.5 the load power factor will be
Option (A)
Ö2/Ö3
Option (B)
1
Option(C)
Ö3/Ö2
Option(D)
Ö3
Correct Option:
()